14 avgusta energosistema iuga Kazahstana stolknulas s sereznym tehnologicheskim naruşeniem. Masştab byl znachitelnym, no normalnyi rejim udalos vosstanovit dostatochno bystro.
Privoju ofisialnuiu hronologiiu sobytii po dannym Energonadzora:
> 14 avgusta v 14:37 deistviem protivoavariinoi avtomatiki (PA) otkliuchilis VL-500 kV L-5300, L-5320 Agadyr-Ulken, L-5394 Semei — Aqtoǧai, VL-500 kV L-5400 Aqtoǧai — Taldyqorǧan.
Na PS Ulken otkliuchilsia V-220 kV L-2303. Na PS Qyzylorda-220 otkliuchilis V-220 kV L-2579, L-2589. Na PS Şu-500 otkliuchilsia V-220 kV L-2253. Na PS Almaty-500 otkliuchilsia V-220 kV L-2193. Iýjnaia zona EES RK i OES SA vydelilis na izolirovannuiu rabotu ot Severnoi zony.
MGES snizila generasiiu s 300 MVt do 0 MVt. Ot komandy OG na UKGES otkliuchilsia GG-1, na ŞGES otkliuchilsia GG-4, na BGES otkliuchilis GG-2,5,8,9. Ogranicheniia summarno sostavili 1236,5 MVt, iz nih: Jambylskaia obl. — 164,8 MVt; Turkestanskaia obl. — 404 MVt; Kyzylordinskaia obl. — 46,6 MVt; Almatinskaia obl. — 300 MVt; Jetysuskaia obl. — 26,6 MVt; Ulytauskaia obl. — 43 MVt; Karagandinskaia obl. — 143 MVt, Abaiskaia obl. — 109 MVt. Obem ogranichenii v SA — 1175 MVt. Uzbekskaia energosistema, v 14:49 po faktu otkliucheniia L-507, vydelilas na izolirovannuiu rabotu. Tadjikskaia energosistema rabotala SAON R=371 MVt. V 19:31 sinhronizirovali Tadjikskuiu energosistemu po L-507.
V 14:47 vkliuchili v rabotu L-5394. V 14:47 dano ukazanie sniat ogranicheniia po potrebiteliam otkliuchennyh deistviem SAON po Sentralnomu regionu. V 14:47 vkliuchili na UK GES GG-1, na ŞGES GG-4. V 15:09 chastichno sniaty ogranicheniia v obeme 17,6 MVt po Kyzylordinskoi obl., na ogranichenii ostaetsia 29 MVt.
Predvaritelnaia prichina nabrosa moşnosti: v 14:37 na Toktogulskoi GES otkliuchilis GG-1, GG-2 s R=625 MVt. GG-3 ostalsia v rabote. V 15:01 vkliuchili iz holodnogo rezerva GG-4, v 15:42 vkliuchili GG-1.
V 15:11 pri sinhronizasii Iýjnoi zony EES RK i OES SA s Severnoi zonoi RK po VL-500 kV L-5300 Agadyr — Ulken deistviem PA otkliuchilis VL-500 kV L-5300, L-5333 Ulken — Şu, L-5313 Ulken — Almaty, L-5363 Ulken — Alma. Deistviem ADS otkliuchilas VL-220 kV L-2283 Ulken — Şyǧanak na PS Ulken. Na PS-7A otkliuchilas ot ChDA VL-220 kV L-2173 Zapadnaia — PS 7A, na PS Zapadnaia otkliuchilsia SV-220 ot MChDA PS Almaty.
V 15:12 AlmTES-2 snizila generasiiu s 200 do 0 MVt, AlmTES-3 — s 82 do 0 MVt. V 15:15 Kapşagaiskaia GES snizila generasiiu s 165 do 0 MVt. Obem ogranichenii — 1740,6 MVt, iz nih: Almatinskaia obl. — 1600 MVt; Jetysuskaia obl. — 140,6 MVt. İtogo na ogranichenii po Iýjnoi zone EES RK — 2667,2 MVt.
V 15:43 vkliuchili v rabotu L-5300. V 15:57 — L-5313. V 16:03 — L-5363. V 16:07 — L-5320. V 16:09 — L-5400. V 16:12 vkliuchili V-220 kV vvodov AT-1, AT-2 na PS Almaty. V 16:14 — vvodov AT-1, AT-2 na PS Alma. V 16:15 — vvodov AT-1 na Taldyqorǧan-500. V 16:15 dana komanda na razvorot stansii AlmTES-2, AlmTES-3, MGES i KapGES. V 16:21 vkliuchili v rabotu L-2253.
V 16:26 proizveli sinhronizasiiu Severnoi zony s Iýjnoi zonoi EES RK i OES SA po VL-500 kV L-5333 na PS Şu. V 16:26 dano ukazanie sniat ogranicheniia v polnom obeme po Almatinskomu regionu. V 16:30 vkliuchili GG-1 na KapGES (razvorot stansii); v 16:57 — GG-1 na MGES (razvorot stansii). V 16:32 vkliuchili v tranzit L-2283. V 16:34 — L-2303. V 16:34 — L-2579, L-2589. V 16:34 dano ukazanie sniat ogranicheniia v polnom obeme po Iýjnomu regionu. V 16:59 ogranicheniia sniaty v polnom obeme.
V 16:52 vkliuchili SV-220 na PS Zapadnaia, v 17:47 na PS-7A vkliuchili v tranzit VL-220 kV L-2173 PS 7A — Zapadnaia. V 16:39 na Almaty vkliuchili v tranzit VL-220 kV L-2193 Almaty — Glavnaia. V 17:04 vkliuchili v rabotu GG-2 na MGES. V 19:36 vkliuchili v rabotu K-1, TG-1 na AlmTES-2 (razvorot stansii); v 19:55 — K-3, TG-1 na AlmTES-3 (razvorot stansii). V 21:49 vkliuchili v rabotu iz holodnogo rezerva TG-3 na AlmTES-3. V 22:01 — TG-5, v 22:10 — K-5 na AlmTES-2. V 22:13 vkliuchili v rabotu K-5 na AlmTES-3.
Chto lichno hotelos by otmetit:
Vchera energosistema iuga strany stolknulas s sereznym tehnologicheskim naruşeniem. Masştab otkliuchenii byl znachitelnym, odnako normalnyi rejim udalos vosstanovit dostatochno bystro.
Hochu v pervuiu ochered otmetit rabotu kolleg-energetikov. V avariinoi situasii mnogoe zavisit ne tolko ot avtomatiki, no i ot togo, naskolko chetko vzaimodeistvuiut dispetchery, elektrostansii, magistralnye i raspredelitelnye setevye kompanii, operativnyi personal. Vchera eta koordinasiia byla obespechena.
Posle razdeleniia energosistemy protivoavariinaia avtomatika lokalizovala naruşenie, a spesialisty pristupili k vosstanovleniiu shemy.
Uje v 16:10 byl vosstanovlen tranzit 500 kV Sever — Vostok — Iýg, v 16:26 naşa energosistema vnov rabotala sinhronno s OES Sentralnoi Azii, posle chego ogranicheniia dlia potrebitelei byli polnostiu sniaty.
Samo sobytie, konechno, trebuet otdelnogo professionalnogo razbora. Neobhodimo poniat prichiny avariinogo disbalansa, posledovatelnost razvitiia naruşeniia i osenit rabotu vseh elementov zaşity i avtomatiki. İz takih situasii nujno delat tehnicheskie vyvody i ispolzovat ih dlia dalneişego povyşeniia nadejnosti EES.
No operativnaia rabota vchera byla deistvitelno slajennoi. V neprostoi situasii energetiki uderjali sistemu pod kontrolem i dostatochno bystro vernuli ee k normalnomu rejimu.
Kollegam, kotorye vchera stoiali na dejurstve na stansiiah, podstansiiah, v dispetcherskih sentrah i setiah, — otdelnaia ogromnaia blagodarnost za professionalnuiu rabotu!